Hager Fox Heating & Air Conditioning is your one-stop solution for HVAC, electrical, and water heater services in Okemos, MI. Our commitment to excellence is unmatched, with a legacy dating back to 1941. We don’t use subcontractors, ensuring that every service is handled by our licensed, insured, and NATE-certified technicians.
Contact Hager Fox Heating & Air Conditioning today at (517) 348-0412 and schedule a service that rocks.

Top-Rated Heating & Cooling Services
We offer top-rated heating and cooling services at Hager Fox Heating & Air Conditioning, specializing in ductless mini-splits, heat pumps, and gas or electric furnaces. Our services include:
- Installation & replacement: Our team provides expert installation and replacement services and customized solutions tailored to your needs and property requirements.
- Repair: We guarantee swift and reliable repair solutions for all HVAC systems and killed technicians equipped to diagnose and resolve issues efficiently, restoring comfort to your home.
- Maintenance: Our expert technicians offer tailored maintenance programs designed to preserve the efficiency and longevity of your HVAC systems. Hager Fox Air Care features exclusive benefits and priority service for members of our maintenance plans.
Air Quality Services in Okemos
Hager Fox Heating & Air Conditioning understands the importance of indoor air quality for your home. Improved IAQ offers numerous benefits, including better respiratory health, reduced allergens, and a more comfortable living environment.
Our comprehensive air quality solutions include:
- Air purifiers: Advanced air purifiers eliminate airborne contaminants like dust, pollen, and pet dander. These systems purify the air in your home, providing a fresh and clean living environment for you and your family.
- Air scrubbers: Cutting-edge air scrubbers remove odors, VOCs, and surface contaminants, ensuring a healthier indoor environment. They purify the air and surfaces in your home, creating a cleaner and more sanitized living space.
- Whole-home humidifiers & dehumidifiers: Whole-home humidifiers maintain optimal moisture levels, reducing dryness and improving overall comfort. Dehumidifiers control excess moisture, preventing mold and mildew growth while enhancing air quality.
Contact our professionals at (517) 348-0412 to schedule IAQ services and experience a healthier, more comfortable living space.
Superior Electrical Services
We pride ourselves on delivering superior electrical services for residential needs. From outlet wiring to whole-home generator installation, our comprehensive electrical solutions cover everything to keep your home powered and safe.
Our services include outlet wiring, electrical panels, outdoor and security lighting, ceiling fan installation, smart home device installation, and more. With a focus on top-priority electrical work, such as generators and EV charging stations, we ensure your home is equipped for modern electrical demands.
Contact us today at (517) 348-0412 to schedule reliable, top-quality electrical services that meet your needs and exceed your expectations.
Expert Water Heater Services
At Hager Fox, we are experts in providing top-notch water heater services. Whether it’s gas, electric, or tankless water heaters, our dedicated sections cover everything you need:
- Installation & replacement: We provide expert installation and replacement services for gas, electric, and tankless water heaters.
- Repair: Our skilled technicians are equipped to diagnose and address issues efficiently, restoring comfort to your home.
- Maintenance: Routine inspections and tune-ups ensure a consistent hot water supply and prevent unexpected breakdowns.
Call today at (517) 348-0412 to schedule same-day water heater repair and installation!
Choose Hager Fox Heating & Air Conditioning in Okemos
We are the preferred option for HVAC, water heater, and electrical services in Okemos, MI. Our licensed, insured, background-checked, and NATE-certified technicians provide replacement quotes and service call estimates. With financing options, instant rebates, and an unwavering commitment to excellence, we ensure 100% satisfaction guaranteed.
For service that rocks, call Hager Fox at (517) 348-0412 and schedule an HVAC, electrical, or water heater service today.
Recent Jobs and Reviews in Okemos, MI
Job Locations and Reviews
Completed annual cooling maintenance on residential HVAC system. Inspected indoor air handler unit and replaced furnace filter with new mesh filter panel installed in metal frame housing. Verified proper airflow through ductwork and connections. Proceeded to outdoor condensing unit for exterior inspection. Examined beige AC unit mounted on plastic pad against building foundation. Inspected fan grille, louvered vents, and refrigerant line connections. Verified electrical conduit routing and manufacturer specifications. Confirmed unit operating within normal parameters with no visible signs of damage or wear. All components functioning properly upon completion of maintenance service. Wore shoe covers per customer request throughout interior portion of service call.
Completed semi-annual air conditioning maintenance inspection on residential HVAC system located in attic space. Performed standard ACM checklist including filter replacement, visual inspection of ductwork and condensate drain line, and equipment operational verification. System components including flexible ductwork, drain piping with mounting straps, and air handling unit were inspected and found to be functioning properly with no immediate service needs identified.
Conducted on-site evaluation for new whole home generator installation at a manufactured home. Assessed existing electrical panel configuration, available space in utility closet, and determined load requirements based on current 200-amp service with dual-column circuit breaker arrangement. Documented panel location, copper conduit routing, and identified optimal transfer switch placement for future generator integration with main electrical system.
Completed comprehensive ComfortGuard Maintenance Package on four-year-old Lennox furnace and air conditioning system. Performed full AC tune-up on outdoor condenser unit, including inspection of fan motor, compressor operation, refrigerant levels, electrical connections, and capacitor testing. Cleaned condenser coils and removed debris accumulation from exterior cabinet panels. Conducted indoor furnace inspection, verifying blower motor operation, heat exchanger integrity, gas valve function, and ignition system performance. Tested all safety controls, measured temperature rise across heat exchanger, and verified proper airflow throughout system. Replaced air filter and documented system operating pressures and temperatures. Both heating and cooling systems operating within manufacturer specifications with no immediate repairs required. Recommended exterior cabinet cleaning for condenser unit to prevent corrosion and maintain efficiency. All diagnostic measurements recorded using calib
Conducted on-site evaluation for air conditioning replacement at residential property. Existing 30-year-old AC unit is non-operational and requires full replacement. Assessed attic-installed HVAC system including Bryant furnace with associated ductwork and determined air conditioning equipment specifications needed for quote preparation. Documented existing equipment configuration, ductwork connections, and installation conditions through photographic evidence to support replacement estimate.
Successfully installed a 75-gallon Bradford White tanked water heater in basement utility area. Completed all necessary plumbing connections including copper supply lines with shut-off valves, proper venting with metallic vent pipe extending to code-compliant termination point, and reconnection of all water supply systems. Installation performed in accordance with mechanical permit requirements and manufacturer specifications.
Completed scheduled Air Care Cooling maintenance on Lennox HVAC system, model 7X5C61A5C+1. Performed comprehensive inspection of evaporator coil assembly, verified A-frame coil configuration and aluminum fin condition, checked refrigerant line connections and insulation integrity, and documented system specifications per manufacturer guidelines.
Completed annual cooling maintenance on residential air conditioning system. Inspected outdoor condenser unit for proper operation, cleared debris from surrounding area, and verified adequate airflow through coil louvers. Replaced dirty air filter with accumulated dust buildup to restore proper system airflow and indoor air quality.
Returned to site to replace defective evaporator coil under warranty coverage. Installed new Lennox evaporator coil (model 29a26) per manufacturer specifications. Evacuated system, charged with proper refrigerant amount as verified by calibrated Elitech LMC-200A refrigerant scale showing 91.9 lbs, and confirmed system operation with all parameters within normal range.
Completed annual cooling maintenance on Bryant condenser unit. Performed comprehensive system inspection, verified temperature differential at 18.7°F indicating proper refrigerant charge and heat exchange, and confirmed unit operational status with all components functioning within manufacturer specifications.
Completed annual HVAC maintenance inspection on residential furnace and air handling system. Performed standard ACM protocol including filter replacement, system diagnostics, and visual inspection of ductwork and components to ensure proper operation for continued heating and cooling efficiency.
Conducted on-site assessment for replacement estimate of 15+ year old natural gas furnace and air conditioning system located in basement. Evaluated existing HVAC installation including furnace with integrated humidifier, PVC condensate drainage lines, ductwork configuration, and exterior electrical service connections to provide comprehensive equipment replacement recommendations for Air Care Member.
Completed installation of 2-ton Lennox air conditioning system with evaporator coil. Installed outdoor condenser unit on base pad at rear of property with proper refrigerant line connections and electrical disconnect. Mounted indoor evaporator coil to existing air handler in basement utility room, connected copper refrigerant lines with insulation, and installed brass service valves. System tested, charged to manufacturer specifications, and verified proper operation of all components.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, checked outdoor unit and found condensate drain line severely out of level, causing drainage issues that triggered safety shutdown. Used precision level to verify and document improper pitch of drain line. Corrected drain line positioning to proper slope for adequate condensate flow, cleared any blockages, and verified system operation restored with proper cooling function throughout home.
Completed annual cooling maintenance on HVAC system. Replaced dirty air filter and evaporator coil pad, both showing significant dust and debris accumulation. Documented condition of evaporator coils which displayed heavy contamination on fins, indicating need for improved filtration and regular maintenance schedule.
Conducted comprehensive site evaluation for replacement of 19-20 year old non-operational natural gas furnace and air conditioning system located in crawlspace. Assessed existing HVAC equipment accessed through exterior basement entry with weathered wooden frame and metal access doors. Documented current air handler unit with reflective foil wrap, flexible ductwork connections, and electrical wiring configuration in confined crawlspace environment. Evaluated structural conditions including exposed insulation, wooden framing, and equipment placement constraints. Provided detailed replacement estimate for complete furnace and A/C system upgrade to restore climate control functionality.
Completed annual cooling maintenance on residential outdoor condensing unit. Performed comprehensive system inspection, verified electrical readings showing 339.9 volts at the unit, cleaned condenser coils, checked refrigerant levels, and ensured all mechanical components were operating within manufacturer specifications.
Conducted on-site evaluation of existing 15-year-old 75-gallon gas-fired water heater for replacement estimate. Inspected unit in basement mechanical room, documenting current condition including rust staining on tank top surface and corrosion present on adjacent piping at floor level. Assessed venting system configuration with existing metallic flue pipe connection and evaluated surrounding plumbing infrastructure including exposed copper lines and drainage systems. Photographed installation area to document spatial constraints, clearances, and existing utility connections for replacement specifications. Verified gas supply routing and evaluated ventilation requirements for new unit installation.
Completed electrical estimate for new whole home generator installation at manufactured home residence. Assessed property electrical infrastructure, load requirements, and optimal placement for 26kW generator system, with customer considering both Generac and Kohler brand options for the installation.
Completed comprehensive estimate for full HVAC system replacement including furnace and air conditioning unit. Both existing Lennox systems are approximately 21 years old and nearing end of serviceable life. Customer requested quote for proactive replacement planned for summer installation, with preference to continue with Lennox brand equipment. Assessed current basement installation including furnace, humidifier, ductwork configuration, and condensate drainage system. Documented existing equipment specifications, electrical panel location, and available workspace for future installation. Photographed current system layout showing furnace unit, wall-mounted humidifier with PVC connections, metallic supply and return ductwork, and overall mechanical room configuration. Provided information regarding available promotions as requested.