When it comes to your home’s HVAC, plumbing, and electrical service needs, having a trusted technician is essential for ensuring comfort, safety, and peace of mind. That’s where Hager Fox Heating & Air Conditioning comes in. We take pride in providing top-notch home services throughout East Lansing and the surrounding area.
If you’re seeking professional HVAC, water heater, or electrical services, look no further than Hager Fox. Schedule your service today by calling us at (517) 348-0412!
Dependable HVAC Services for East Lansing Families
At Hager Fox, we offer a wide range of HVAC services to cater to the unique needs of East Lansing families. Our expert technicians are skilled in handling various HVAC systems, including:
- Ductless mini-splits: Perfect for efficient zoned cooling and heating, providing individualized comfort for different areas of your home.Â
- Heat pumps: Versatile systems that heat and cool your home efficiently, ideal for moderate climates like East Lansing.Â
- Gas & electric furnaces: We specialize in installing, repairing, and maintaining furnaces to keep your home warm during the winter.Â
- Central AC: Our technicians are experienced in installing and servicing central air conditioning systems, ensuring you stay cool all summer.
Installation & Replacement
When it comes to HVAC installations and replacements, Hager Fox is your go-to service provider. If you notice any of the following signs, it might be time to consider upgrading your HVAC system:
- Frequent breakdowns and costly repairsÂ
- Rising energy bills indicating reduced efficiency
- Uneven heating or cooling throughout your home
- Outdated system unable to meet your family’s needs
Repair
HVAC systems can face various issues over time, affecting their performance and comfort. Count on Hager Fox for HVAC repair services to address a variety of common problems, such as:
- Airflow issues due to clogged filters or ductwork problems
- Thermostat malfunctions and inaccurate temperature readings
- Strange noises coming from the HVAC unitÂ
- Inconsistent heating or cooling
Maintenance
Preventative maintenance is critical to extending the life span of your HVAC equipment and avoiding costly repairs. Our HVAC maintenance services offer the following benefits:
- Improved system efficiency and energy savings
- Enhanced indoor air quality, promoting a healthier living environment
- Early detection of potential issues, preventing major breakdowns
- Prolonged HVAC system life span
East Lansing Air Quality ServicesÂ
At Hager Fox, we understand the importance of indoor air quality. We offer a variety of indoor air quality solutions suitable for a broad range of applications, including:
- Air purifiers: Remove pollutants, allergens, and particles from the air, promoting cleaner and fresher indoor air.Â
- Air scrubbers: Help eliminate odors, smoke, and volatile organic compounds from your home.Â
- Whole-home humidifiers & dehumidifiers: Maintain optimal humidity levels for better comfort and health.Â
Schedule indoor air quality services for your East Lansing home by calling Hager Fox at (517) 348-0412 today!
Reliable Water Heater Services
In addition to HVAC services, Hager Fox provides reliable water heater solutions to families throughout East Lansing and beyond. Our skilled technicians can handle:
- Water heater installation & replacement: Whether you prefer gas, electric, or tankless water heaters, we’ve got you covered with the best systems.
- Water heater repair: Prompt and efficient repair services to ensure hot water is always available when you need it most.
- Water heater maintenance: Regular maintenance to prevent breakdowns and extend the life of your water heater unit.
Get the fast, efficient water heater services you seek by calling (517) 348-0412 to schedule service with our water heater experts today!Â
Expert Electrical Services
Beyond heating, cooling, and water heaters, Hager Fox offers expert electrical services, including:
- Outlet & switch repair & replacement
- Electrical panel upgrades
- Circuit breakers
- Whole-home generators
- Lighting installation & repair
- Ceiling fan installation & repair
- Code corrections
- Appliance installation
- Wiring & rewiring
- And much more!
Allow our team to ensure functionality and safety in your home through our top-quality electrical solutions. Call (517) 348-0412 to request electrical service from Hager Fox today!
Why Choose Hager Fox Heating & Air Conditioning in East Lansing?
There are several reasons why Hager Fox should be your preferred choice for quality HVAC, water heater, and electrical services, including:
- Licensed & insured technicians: Our team consists of background-checked, NATE-certified technicians who deliver quality service with professionalism.Â
- Service all brands: We are well-equipped to handle the HVAC and electrical systems of all brands, including Lennox, Mitsubishi, and Kohler.Â
- Free estimates: We provide free estimates for replacement quotes and service calls, ensuring transparency and affordability.Â
- Financing options & instant rebates: We offer flexible financing options and instant rebates to make our services more accessible and budget-friendly.Â
- 100% satisfaction guaranteed: Customer satisfaction is our top priority, and we guarantee your complete satisfaction with our services.Â
Don’t hesitate to choose Hager Fox Heating & Air Conditioning for all your HVAC, water heater, and electrical service needs. Schedule your service today by calling (517) 348-0412 now!Â
Recent Jobs and Reviews in East Lansing, MI
Job Locations and Reviews
Performed routine preventative maintenance on Lennox outdoor condensing unit. Inspected condenser coils, fan operation, refrigerant lines, and electrical connections; confirmed unit operating within normal parameters with no deficiencies noted.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, checked refrigerant levels, cleaned coils, verified proper airflow through grilles, and tested fan operation. Unit operating within normal parameters with no issues identified.
Completed annual HVAC maintenance inspection on residential air handler and furnace system. Identified filter requiring replacement and installed new filter to ensure proper airflow and system efficiency. Performed comprehensive system check of internal components including blower motors, gas valve assembly, control board, and electrical connections; all components found to be operating within normal parameters.
# HVAC Annual Maintenance Completed Performed comprehensive annual cooling maintenance on residential Bryant HVAC system located in basement mechanical room. Conducted thorough inspection of furnace unit and associated components including water heating equipment, ductwork, and piping systems. ## Work Performed Inspected Bryant furnace unit and verified all technical specifications and safety labels were legible and intact. Examined PVC condensate drainage system, metal piping, valves, and flexible duct connections for proper operation and secure mounting. Verified water heater controls and connections were functioning correctly. Discovered severely clogged air filter with heavy accumulation of dust, dirt, and debris significantly restricting airflow through the HVAC system. The metal mesh filter exhibited substantial particulate buildup concentrated in multiple areas, indicating extended service interval without replacement. This condition would have reduced system efficiency and
Completed scheduled Air Care Cooling maintenance on HVAC system. Inspected and documented evaporator coil assembly with serpentine refrigerant tubes, verified blower motor and wheel operation, and examined air filtration system with honeycomb mesh filter in proper position. All components photographed and found operating within normal parameters during routine preventive maintenance visit.
Responded to no-heat call on 2017 Monnex four-star furnace system. Upon arrival, found unit completely non-operational with suspected control board communication failure. Performed diagnostic testing on internal components, blower motor assembly, and electrical connections. Inspected thermostat programming and verified proper communication between wall-mounted digital thermostat set to 72°F and furnace control system. Documented furnace interior components and thermostat display for service records.
Completed annual HVAC maintenance inspection including filter evaluation and evaporator coil assessment. Filter showed visible debris accumulation and was documented; evaporator coil exhibited moisture condensation consistent with normal operation, with refrigerant lines and filter-drier component verified to be in proper working condition.
Responded to service call for 2-month-old furnace experiencing rumbling vibration during shutdown cycle. Performed diagnostic inspection of HVAC system and Honeywell control components, examining ductwork plenum, mounting hardware, and blower assembly for loose connections or debris that could cause operational noise. Addressed issue under active parts and labor warranty coverage.
# HVAC Maintenance Service Completed Performed scheduled air conditioning maintenance on residential HVAC system. Upon inspection, discovered severely frosted evaporator coils indicating restricted airflow or potential refrigerant issues. The frost accumulation was extensive across all serpentine coil tubes and header manifold, requiring immediate attention. Noted corrosion present in drain pan beneath coils, suggesting ongoing moisture management concerns. Replaced air filter and evaporator pad as part of routine maintenance protocol. Inspected air handler unit and associated ductwork connections. All manufacturer labels and safety warnings verified as intact and legible. Condensate drain system checked for proper operation. Documented system condition through photographic evidence for maintenance records. System requires monitoring for proper defrost cycling and airflow restoration following filter replacement.
Completed ACM preventive maintenance on Lennox split system. Inspected outdoor condenser unit and indoor evaporator coil, verified refrigerant lines and connections, and brought replacement filter for system renewal. All components found operating within normal parameters.
Completed annual AC maintenance checkup on Bryant Evolution System with Plus 90i furnace as part of membership program. Performed comprehensive inspection of air handler, condenser unit, and ductwork. Evaluated and documented existing air filter condition, which showed normal dust accumulation. Inspected refrigerant lines, electrical connections, and thermostat operation. Verified proper airflow through supply plenum and ductwork. All components found operating within normal parameters with no deficiencies noted. System running efficiently with no repairs required at this time.
Completed annual cooling maintenance on residential HVAC system, including inspection of outdoor condenser unit and replacement of furnace filters. Performed comprehensive system evaluation, renewed air care membership, and conducted pre-season cooling assessment to ensure optimal performance for upcoming warmer months.
# HVAC Maintenance - ACM Service Completed Performed comprehensive Air Care Cooling maintenance on residential HVAC system located in basement mechanical room. Conducted thorough inspection of air handling unit mounted on elevated green support rails with associated ductwork and piping systems. ## Equipment Inspection and Findings Inspected primary air handling unit and evaporator coil assembly. Visual examination revealed significant biological growth present on evaporator coil surfaces, evidenced by yellow-green substance covering portions of the aluminum fin array, particularly concentrated along top edges and distributed across multiple sections of the coil. This growth pattern indicates moisture accumulation and potential drainage concerns that can reduce system efficiency and indoor air quality. Verified all refrigerant line connections, including copper lines with brass fittings and associated black insulation material. Examined PVC condensate drainage piping with curved elb
Completed annual AC tune-up on a residential air conditioning system as part of preventative maintenance membership. Performed comprehensive inspection of the air handling unit, including examination of refrigerant lines, copper piping, and internal components. Evaluated and documented the condition of the 18x25x4 air filter, which showed normal accumulation of dirt and debris consistent with regular use. All system components were inspected and found to be operating within normal parameters with no issues identified requiring immediate attention.
Performed routine air handler maintenance including inspection and filter replacement. Filter showed moderate dust accumulation with visible spotting; installed new filter with proper orientation and secured access panel. Inspected associated condensate pump assembly and PVC drain lines in attic space; confirmed proper operation and verified all connections were secure with no signs of leakage or blockage.
Completed annual air conditioning tune-up and maintenance on residential outdoor condenser unit. Performed comprehensive system inspection including checking refrigerant levels, testing electrical connections at disconnect box, cleaning condenser coils, verifying proper airflow through louvered panels, and confirming fan operation. Unit operating within normal parameters with no issues identified. Documented equipment condition with photos showing condenser positioned on pad with appropriate clearances from structure.
Completed annual cooling maintenance on Lennox HVAC system. Performed comprehensive inspection of evaporator coil assembly, refrigerant lines, and blower components. Replaced air filter and evaporator pad as part of routine maintenance protocol. Verified all electrical connections, checked refrigerant line insulation integrity, and confirmed proper operation of all system components. Unit operating within normal parameters upon completion.
Completed scheduled Air Care Heating and Cooling maintenance service, replacing the MANN+HUMMEL air filter in the HVAC system. Inspected air handler unit, water heater, and associated plumbing connections including ball valves and PVC piping, confirming all components were operating properly and system was functioning as designed.
Successfully installed a 40-gallon Bradford White natural draft water heater, model RG240S6N, in basement utility room. Completed all copper piping connections to the unit, including hot and cold water lines with appropriate shut-off valves and pressure relief valve installation. Connected natural draft flue venting system to existing vent stack for proper exhaust of combustion gases. Secured unit with proper mounting brackets on concrete floor and verified all plumbing connections for leak-free operation. Installation included electrical wiring connections and compliance with manufacturer specifications for professional installation requirements.
Performed comprehensive annual heating check and tune-up on residential gas furnace system. Conducted thorough inspection of all internal components including heat exchanger, burner assembly, blower motor, gas valve, ignition system, and electrical connections. Verified proper burner operation with clean blue flame pattern across all ports. Tested and confirmed blower motor function, checked all electrical connections and wiring throughout the unit, and inspected control board operation. Cleaned burner assembly and internal components as needed, verified proper airflow, and ensured all safety controls were functioning correctly. System operating efficiently with no issues identified.