Top HVAC Service in East Lansing, MI | Repair & Replacement

HVAC, Water Heater & Electrical Services in East Lansing, MI

When it comes to your home’s HVAC, plumbing, and electrical service needs, having a trusted technician is essential for ensuring comfort, safety, and peace of mind. That’s where Hager Fox Heating & Air Conditioning comes in. We take pride in providing top-notch home services throughout East Lansing and the surrounding area.

If you’re seeking professional HVAC, water heater, or electrical services, look no further than Hager Fox. Schedule your service today by calling us at (517) 209-0130!

Hager Fox plumber installing a water heater in a residence

Dependable HVAC Services for East Lansing Families

At Hager Fox, we offer a wide range of HVAC services to cater to the unique needs of East Lansing families. Our expert technicians are skilled in handling various HVAC systems, including:

  • Ductless mini-splits: Perfect for efficient zoned cooling and heating, providing individualized comfort for different areas of your home. 
  • Heat pumps: Versatile systems that heat and cool your home efficiently, ideal for moderate climates like East Lansing. 
  • Gas & electric furnaces: We specialize in installing, repairing, and maintaining furnaces to keep your home warm during the winter. 
  • Central AC: Our technicians are experienced in installing and servicing central air conditioning systems, ensuring you stay cool all summer.

Installation & Replacement

When it comes to HVAC installations and replacements, Hager Fox is your go-to service provider. If you notice any of the following signs, it might be time to consider upgrading your HVAC system:

  • Frequent breakdowns and costly repairs 
  • Rising energy bills indicating reduced efficiency
  • Uneven heating or cooling throughout your home
  • Outdated system unable to meet your family’s needs

Repair

HVAC systems can face various issues over time, affecting their performance and comfort. Count on Hager Fox for HVAC repair services to address a variety of common problems, such as:

  • Airflow issues due to clogged filters or ductwork problems
  • Thermostat malfunctions and inaccurate temperature readings
  • Strange noises coming from the HVAC unit 
  • Inconsistent heating or cooling

Maintenance

Preventative maintenance is critical to extending the life span of your HVAC equipment and avoiding costly repairs. Our HVAC maintenance services offer the following benefits:

  • Improved system efficiency and energy savings
  • Enhanced indoor air quality, promoting a healthier living environment
  • Early detection of potential issues, preventing major breakdowns
  • Prolonged HVAC system life span

East Lansing Air Quality Services 

At Hager Fox, we understand the importance of indoor air quality. We offer a variety of indoor air quality solutions suitable for a broad range of applications, including:

  • Air purifiers: Remove pollutants, allergens, and particles from the air, promoting cleaner and fresher indoor air. 
  • Air scrubbers: Help eliminate odors, smoke, and volatile organic compounds from your home. 
  • Whole-home humidifiers & dehumidifiers: Maintain optimal humidity levels for better comfort and health. 

Schedule indoor air quality services for your East Lansing home by calling Hager Fox at (517) 209-0130 today!

Reliable Water Heater Services

In addition to HVAC services, Hager Fox provides reliable water heater solutions to families throughout East Lansing and beyond. Our skilled technicians can handle:

  • Water heater installation & replacement: Whether you prefer gas, electric, or tankless water heaters, we’ve got you covered with the best systems.
  • Water heater repair: Prompt and efficient repair services to ensure hot water is always available when you need it most.
  • Water heater maintenance: Regular maintenance to prevent breakdowns and extend the life of your water heater unit.

Get the fast, efficient water heater services you seek by calling (517) 209-0130 to schedule service with our water heater experts today! 

Expert Electrical Services

Beyond heating, cooling, and water heaters, Hager Fox offers expert electrical services, including:

  • Outlet & switch repair & replacement
  • Electrical panel upgrades
  • Circuit breakers
  • Whole-home generators
  • Lighting installation & repair
  • Ceiling fan installation & repair
  • Code corrections
  • Appliance installation
  • Wiring & rewiring
  • And much more!

Allow our team to ensure functionality and safety in your home through our top-quality electrical solutions. Call (517) 209-0130 to request electrical service from Hager Fox today!

Why Choose Hager Fox Heating & Air Conditioning in East Lansing?

There are several reasons why Hager Fox should be your preferred choice for quality HVAC, water heater, and electrical services, including:

  • Licensed & insured technicians: Our team consists of background-checked, NATE-certified technicians who deliver quality service with professionalism. 
  • Service all brands: We are well-equipped to handle the HVAC and electrical systems of all brands, including Lennox, Mitsubishi, and Kohler. 
  • Free estimates: We provide free estimates for replacement quotes and service calls, ensuring transparency and affordability. 
  • Financing options & instant rebates: We offer flexible financing options and instant rebates to make our services more accessible and budget-friendly. 
  • 100% satisfaction guaranteed: Customer satisfaction is our top priority, and we guarantee your complete satisfaction with our services. 

Don’t hesitate to choose Hager Fox Heating & Air Conditioning for all your HVAC, water heater, and electrical service needs. Schedule your service today by calling (517) 209-0130 now! 

Recent Jobs and Reviews in East Lansing, MI

East Lansing, MI at a glance

Hager Fox Heating & Air Conditioning has completed 20 jobs in East Lansing, MI in August 2026.

The most recent job was on August 25, 2026.

Job Locations and Reviews

Completed routine AC tune-up on 6-year-old outdoor condensing unit with no reported issues or concerns. Performed standard preventative maintenance procedures including system inspection, thermostat verification (Sensi digital model reading 72°F in heating mode), and equipment assessment. Furnace model TM9V090B12MP11A located in basement was observed but not serviced per customer request, with tune-up limited to air conditioning system only.
Completed routine AC tune-up on 6-year-old outdoor condensing unit with no reported issues or concerns. Performed standard preventative maintenance procedures including system inspection, thermostat verification (Sensi digital model reading 72°F in heating mode), and equipment assessment. Furnace model TM9V090B12MP11A located in basement was observed but not serviced per customer request, with tune-up limited to air conditioning system only.
HF G.
HF G. Checked in
Completed routine AC tune-up on 6-year-old outdoor condensing unit with no reported issues or concerns. Performed standard preventative maintenance procedures including system inspection, thermostat verification (Sensi digital model reading 72°F in heating mode), and equipment assessment. Furnace model TM9V090B12MP11A located in basement was observed but not serviced per customer request, with tune-up limited to air conditioning system only.
East Lansing, MI 48823
Completed routine preventive maintenance on HVAC system. Inspected existing air filtration system, including both the permanent washable mesh filter in the return air housing and the standard pleated disposable filter. Both filters showed moderate dust accumulation but remained functional. Verified proper filter installation and airflow pathways. System operational upon completion of maintenance inspection.
Completed routine preventive maintenance on HVAC system. Inspected existing air filtration system, including both the permanent washable mesh filter in the return air housing and the standard pleated disposable filter. Both filters showed moderate dust accumulation but remained functional. Verified proper filter installation and airflow pathways. System operational upon completion of maintenance inspection.
HF G.
HF G. Checked in
Completed routine preventive maintenance on HVAC system. Inspected existing air filtration system, including both the permanent washable mesh filter in the return air housing and the standard pleated disposable filter. Both filters showed moderate dust accumulation but remained functional. Verified proper filter installation and airflow pathways. System operational upon completion of maintenance inspection.
East Lansing, MI 48823
East Lansing, MI - Completed installation of two high-efficiency gas furnaces in attic space, including a 110,000 BTU unit and a 90,000 BTU unit. Removed existing furnace and replaced with updated equipment, reconnected all ductwork, electrical connections, and PVC condensate drain lines. Obtained mechanical permit, tested system operation, and verified proper airflow and safety controls on both units.
HF G.
HF G. Checked in
Completed installation of two high-efficiency gas furnaces in attic space, including a 110,000 BTU unit and a 90,000 BTU unit. Removed existing furnace and replaced with updated equipment, reconnected all ductwork, electrical connections, and PVC condensate drain lines. Obtained mechanical permit, tested system operation, and verified proper airflow and safety controls on both units.
East Lansing, MI 48823
Conducted comprehensive site assessment for complete HVAC system replacement on residential property with 16-year-old furnace and air conditioning unit. Evaluated existing outdoor condenser unit positioned against exterior wall with adequate clearance and landscaping, inspected electrical service panel to verify circuit capacity and breaker configuration for new equipment installation. Discussed customer requirements for split-zone climate control system to provide independent temperature management between upper and lower floors, documented current system specifications and electrical infrastructure to develop tailored replacement proposal for dual-zone HVAC solution.
Conducted comprehensive site assessment for complete HVAC system replacement on residential property with 16-year-old furnace and air conditioning unit. Evaluated existing outdoor condenser unit positioned against exterior wall with adequate clearance and landscaping, inspected electrical service panel to verify circuit capacity and breaker configuration for new equipment installation. Discussed customer requirements for split-zone climate control system to provide independent temperature management between upper and lower floors, documented current system specifications and electrical infrastructure to develop tailored replacement proposal for dual-zone HVAC solution.
HF A.
HF A. Checked in
Conducted comprehensive site assessment for complete HVAC system replacement on residential property with 16-year-old furnace and air conditioning unit. Evaluated existing outdoor condenser unit positioned against exterior wall with adequate clearance and landscaping, inspected electrical service panel to verify circuit capacity and breaker configuration for new equipment installation. Discussed customer requirements for split-zone climate control system to provide independent temperature management between upper and lower floors, documented current system specifications and electrical infrastructure to develop tailored replacement proposal for dual-zone HVAC solution.
East Lansing, MI 48823
Completed routine ComfortGuard maintenance visit on HVAC system. Performed comprehensive inspection of unit components including control board, electrical connections, refrigerant lines, and air return system. Noted dust accumulation on return air grille requiring attention during service, and verified all internal wiring, relay connections, and electronic controls were functioning properly.
Completed routine ComfortGuard maintenance visit on HVAC system. Performed comprehensive inspection of unit components including control board, electrical connections, refrigerant lines, and air return system. Noted dust accumulation on return air grille requiring attention during service, and verified all internal wiring, relay connections, and electronic controls were functioning properly.
HF G.
HF G. Checked in
Completed routine ComfortGuard maintenance visit on HVAC system. Performed comprehensive inspection of unit components including control board, electrical connections, refrigerant lines, and air return system. Noted dust accumulation on return air grille requiring attention during service, and verified all internal wiring, relay connections, and electronic controls were functioning properly.
East Lansing, MI 48823
Completed comprehensive AC tune-up on 10-year-old Carrier system experiencing musty odor from supply vents despite proper cooling operation. Performed full preventive maintenance protocol including condenser coil cleaning to address visible algae growth on outdoor unit, evaporator coil inspection and cleaning, condensate drain line flush and treatment, air filter replacement, refrigerant charge verification, electrical connection inspection, and airflow assessment. Addressed humidity-related odor issue by treating drain system and verifying proper condensate removal. All components tested and confirmed operational within manufacturer specifications upon completion.
Completed comprehensive AC tune-up on 10-year-old Carrier system experiencing musty odor from supply vents despite proper cooling operation. Performed full preventive maintenance protocol including condenser coil cleaning to address visible algae growth on outdoor unit, evaporator coil inspection and cleaning, condensate drain line flush and treatment, air filter replacement, refrigerant charge verification, electrical connection inspection, and airflow assessment. Addressed humidity-related odor issue by treating drain system and verifying proper condensate removal. All components tested and confirmed operational within manufacturer specifications upon completion.
HF N.
HF N. Checked in
Completed comprehensive AC tune-up on 10-year-old Carrier system experiencing musty odor from supply vents despite proper cooling operation. Performed full preventive maintenance protocol including condenser coil cleaning to address visible algae growth on outdoor unit, evaporator coil inspection and cleaning, condensate drain line flush and treatment, air filter replacement, refrigerant charge verification, electrical connection inspection, and airflow assessment. Addressed humidity-related odor issue by treating drain system and verifying proper condensate removal. All components tested and confirmed operational within manufacturer specifications upon completion.
East Lansing, MI 48823
Completed scheduled maintenance on Concorde air conditioning system. Performed system diagnostics including temperature differential measurements across evaporator coil, verified proper refrigerant operation, and inspected outdoor condenser unit for optimal performance. All components operating within normal parameters upon completion of tune-up service.
Completed scheduled maintenance on Concorde air conditioning system. Performed system diagnostics including temperature differential measurements across evaporator coil, verified proper refrigerant operation, and inspected outdoor condenser unit for optimal performance. All components operating within normal parameters upon completion of tune-up service.
HF N.
HF N. Checked in
Completed scheduled maintenance on Concorde air conditioning system. Performed system diagnostics including temperature differential measurements across evaporator coil, verified proper refrigerant operation, and inspected outdoor condenser unit for optimal performance. All components operating within normal parameters upon completion of tune-up service.
East Lansing, MI 48823
Completed installation of Navien NPE-240A2 tankless water heater in mechanical room. Mounted unit to wall, connected hot and cold water supply lines using PEX piping with appropriate shut-off valves and brass fittings, installed yellow flexible gas line connection, and ran white PVC exhaust and intake venting through exterior wall. Established electrical connection and configured digital control panel. Modified floor drain area with PVC drainage piping to accommodate condensate discharge requirements. All connections tested and verified for proper operation. Installation completed in accordance with manufacturer specifications and local mechanical permit requirements.
Completed installation of Navien NPE-240A2 tankless water heater in mechanical room. Mounted unit to wall, connected hot and cold water supply lines using PEX piping with appropriate shut-off valves and brass fittings, installed yellow flexible gas line connection, and ran white PVC exhaust and intake venting through exterior wall. Established electrical connection and configured digital control panel. Modified floor drain area with PVC drainage piping to accommodate condensate discharge requirements. All connections tested and verified for proper operation. Installation completed in accordance with manufacturer specifications and local mechanical permit requirements.
HF W.
HF W. Checked in
Completed installation of Navien NPE-240A2 tankless water heater in mechanical room. Mounted unit to wall, connected hot and cold water supply lines using PEX piping with appropriate shut-off valves and brass fittings, installed yellow flexible gas line connection, and ran white PVC exhaust and intake venting through exterior wall. Established electrical connection and configured digital control panel. Modified floor drain area with PVC drainage piping to accommodate condensate discharge requirements. All connections tested and verified for proper operation. Installation completed in accordance with manufacturer specifications and local mechanical permit requirements.
East Lansing, MI 48823
Completed comprehensive annual tune-up on 12-year-old Bryant air conditioning system with 2022 condenser model. Performed full inspection of outdoor condensing unit, verified proper operation of compressor and fan motor, checked refrigerant levels and pressures, cleaned condenser coils, and tested electrical connections. System found to be operating within normal parameters with no deficiencies noted.
Completed comprehensive annual tune-up on 12-year-old Bryant air conditioning system with 2022 condenser model. Performed full inspection of outdoor condensing unit, verified proper operation of compressor and fan motor, checked refrigerant levels and pressures, cleaned condenser coils, and tested electrical connections. System found to be operating within normal parameters with no deficiencies noted.
HF R.
HF R. Checked in
Completed comprehensive annual tune-up on 12-year-old Bryant air conditioning system with 2022 condenser model. Performed full inspection of outdoor condensing unit, verified proper operation of compressor and fan motor, checked refrigerant levels and pressures, cleaned condenser coils, and tested electrical connections. System found to be operating within normal parameters with no deficiencies noted.
East Lansing, MI 48823
Completed comprehensive preventive maintenance on residential air conditioning system. Performed full AC tune-up including inspection of thermostat operation (ecobee smart thermostat confirmed functioning properly at 78°F with hold setting at 70°F), evaluated air filter condition (pleated filter showed moderate dust accumulation), checked system components, and verified proper system operation. Unit running efficiently with no issues identified at time of service.
Completed comprehensive preventive maintenance on residential air conditioning system. Performed full AC tune-up including inspection of thermostat operation (ecobee smart thermostat confirmed functioning properly at 78°F with hold setting at 70°F), evaluated air filter condition (pleated filter showed moderate dust accumulation), checked system components, and verified proper system operation. Unit running efficiently with no issues identified at time of service.
HF G.
HF G. Checked in
Completed comprehensive preventive maintenance on residential air conditioning system. Performed full AC tune-up including inspection of thermostat operation (ecobee smart thermostat confirmed functioning properly at 78°F with hold setting at 70°F), evaluated air filter condition (pleated filter showed moderate dust accumulation), checked system components, and verified proper system operation. Unit running efficiently with no issues identified at time of service.
East Lansing, MI 48823
Completed annual cooling maintenance on outdoor condensing unit. Upon inspection, discovered a large bird's nest built within the equipment housing around wiring and components. Removed nest material from unit to prevent potential electrical hazards, airflow restrictions, and equipment damage. Performed standard ACM protocol including inspection of condenser coils, fan assembly, electrical connections, capacitor, and condensate drainage system. All components found in operational condition following nest removal and cleaning. Unit tested and operating within normal parameters.
Completed annual cooling maintenance on outdoor condensing unit. Upon inspection, discovered a large bird's nest built within the equipment housing around wiring and components. Removed nest material from unit to prevent potential electrical hazards, airflow restrictions, and equipment damage. Performed standard ACM protocol including inspection of condenser coils, fan assembly, electrical connections, capacitor, and condensate drainage system. All components found in operational condition following nest removal and cleaning. Unit tested and operating within normal parameters.
HF R.
HF R. Checked in
Completed annual cooling maintenance on outdoor condensing unit. Upon inspection, discovered a large bird's nest built within the equipment housing around wiring and components. Removed nest material from unit to prevent potential electrical hazards, airflow restrictions, and equipment damage. Performed standard ACM protocol including inspection of condenser coils, fan assembly, electrical connections, capacitor, and condensate drainage system. All components found in operational condition following nest removal and cleaning. Unit tested and operating within normal parameters.
East Lansing, MI 48823
Completed annual cooling maintenance on Lennox HVAC system. Inspected thermostat operation showing proper functionality at 72° with system in cooling mode. Identified and documented debris accumulation in drain pan area requiring attention to prevent potential drainage issues and maintain system efficiency.
Completed annual cooling maintenance on Lennox HVAC system. Inspected thermostat operation showing proper functionality at 72° with system in cooling mode. Identified and documented debris accumulation in drain pan area requiring attention to prevent potential drainage issues and maintain system efficiency.
HF G.
HF G. Checked in
Completed annual cooling maintenance on Lennox HVAC system. Inspected thermostat operation showing proper functionality at 72° with system in cooling mode. Identified and documented debris accumulation in drain pan area requiring attention to prevent potential drainage issues and maintain system efficiency.
East Lansing, MI 48823
Conducted full system evaluation for residential HVAC replacement. Assessed 16-year-old furnace and 10-year-old air conditioning system currently experiencing operational failure. Documented existing equipment configuration in basement mechanical room including vertical furnace unit with ductwork connections and outdoor condensing unit mounted on exterior wall. Photographed current system specifications, nameplate data, and installation conditions to provide comprehensive replacement estimate. Customer requires expedited replacement within the next couple weeks due to non-functional cooling system.
Conducted full system evaluation for residential HVAC replacement. Assessed 16-year-old furnace and 10-year-old air conditioning system currently experiencing operational failure. Documented existing equipment configuration in basement mechanical room including vertical furnace unit with ductwork connections and outdoor condensing unit mounted on exterior wall. Photographed current system specifications, nameplate data, and installation conditions to provide comprehensive replacement estimate. Customer requires expedited replacement within the next couple weeks due to non-functional cooling system.
HF A.
HF A. Checked in
Conducted full system evaluation for residential HVAC replacement. Assessed 16-year-old furnace and 10-year-old air conditioning system currently experiencing operational failure. Documented existing equipment configuration in basement mechanical room including vertical furnace unit with ductwork connections and outdoor condensing unit mounted on exterior wall. Photographed current system specifications, nameplate data, and installation conditions to provide comprehensive replacement estimate. Customer requires expedited replacement within the next couple weeks due to non-functional cooling system.
East Lansing, MI 48823
Completed annual maintenance on a 10-year-old Bryant Evolution Connex central air conditioning system. Performed comprehensive tune-up including inspection of outdoor condenser unit, verification of refrigerant lines and service valves, and confirmed proper operation of digital thermostat. System found operating within normal parameters with no deficiencies noted.
Completed annual maintenance on a 10-year-old Bryant Evolution Connex central air conditioning system. Performed comprehensive tune-up including inspection of outdoor condenser unit, verification of refrigerant lines and service valves, and confirmed proper operation of digital thermostat. System found operating within normal parameters with no deficiencies noted.
HF G.
HF G. Checked in
Completed annual maintenance on a 10-year-old Bryant Evolution Connex central air conditioning system. Performed comprehensive tune-up including inspection of outdoor condenser unit, verification of refrigerant lines and service valves, and confirmed proper operation of digital thermostat. System found operating within normal parameters with no deficiencies noted.
East Lansing, MI 48823
Successfully installed two high-efficiency furnaces in basement location: one 110,000 BTU unit and one 90,000 BTU unit. Both systems were mounted on wooden platforms with proper clearances, connected to existing ductwork using flexible ducting, and vented to exterior using white PVC intake and exhaust piping. Electrical connections were completed with appropriate conduit and junction boxes, all work performed to code specifications under mechanical permit for furnace replacement and reconnection.
Successfully installed two high-efficiency furnaces in basement location: one 110,000 BTU unit and one 90,000 BTU unit. Both systems were mounted on wooden platforms with proper clearances, connected to existing ductwork using flexible ducting, and vented to exterior using white PVC intake and exhaust piping. Electrical connections were completed with appropriate conduit and junction boxes, all work performed to code specifications under mechanical permit for furnace replacement and reconnection.
HF P.
HF P. Checked in
Successfully installed two high-efficiency furnaces in basement location: one 110,000 BTU unit and one 90,000 BTU unit. Both systems were mounted on wooden platforms with proper clearances, connected to existing ductwork using flexible ducting, and vented to exterior using white PVC intake and exhaust piping. Electrical connections were completed with appropriate conduit and junction boxes, all work performed to code specifications under mechanical permit for furnace replacement and reconnection.
East Lansing, MI 48823
Responded to emergency service call for reported gas odor from 7-year-old furnace in basement, which had been shut down for safety. Upon arrival, performed comprehensive safety inspection of gas furnace and all connections. Inspected blower motor assembly, gas valve, electrical connections, and all internal components for potential gas leaks or failures. Examined combustion chamber, heat exchanger, and burner assembly for cracks or deterioration that could cause gas odor. Tested all gas line connections, fittings, and the main gas valve using leak detection methods. Verified proper venting through PVC intake and exhaust pipes. Cleaned debris from interior cabinet and checked all wiring harnesses and electrical connections for damage. Inspected condensate drain system and associated plumbing connections. Unit required further evaluation to determine source of gas odor before safe return to operation.
Responded to emergency service call for reported gas odor from 7-year-old furnace in basement, which had been shut down for safety. Upon arrival, performed comprehensive safety inspection of gas furnace and all connections. Inspected blower motor assembly, gas valve, electrical connections, and all internal components for potential gas leaks or failures. Examined combustion chamber, heat exchanger, and burner assembly for cracks or deterioration that could cause gas odor. Tested all gas line connections, fittings, and the main gas valve using leak detection methods. Verified proper venting through PVC intake and exhaust pipes. Cleaned debris from interior cabinet and checked all wiring harnesses and electrical connections for damage. Inspected condensate drain system and associated plumbing connections. Unit required further evaluation to determine source of gas odor before safe return to operation.
HF R.
HF R. Checked in
Responded to emergency service call for reported gas odor from 7-year-old furnace in basement, which had been shut down for safety. Upon arrival, performed comprehensive safety inspection of gas furnace and all connections. Inspected blower motor assembly, gas valve, electrical connections, and all internal components for potential gas leaks or failures. Examined combustion chamber, heat exchanger, and burner assembly for cracks or deterioration that could cause gas odor. Tested all gas line connections, fittings, and the main gas valve using leak detection methods. Verified proper venting through PVC intake and exhaust pipes. Cleaned debris from interior cabinet and checked all wiring harnesses and electrical connections for damage. Inspected condensate drain system and associated plumbing connections. Unit required further evaluation to determine source of gas odor before safe return to operation.
East Lansing, MI 48823
Completed comprehensive 5-year ComfortGuard maintenance visit on HVAC system. Performed thorough inspection of evaporator coil assembly, which showed moderate dust and particulate accumulation on the honeycomb mesh surface with visible discoloration throughout. Inspected drainage line and refrigerant conduit for proper operation and positioning. Removed and evaluated pleated air filter, which displayed dust buildup consistent with normal operational use. Filter frame and internal accordion-style pleated media were examined for structural integrity and airflow restriction. Verified all frame fasteners, rivets, and housing components were secure and properly sealed. System components were documented photographically for maintenance records.
Completed comprehensive 5-year ComfortGuard maintenance visit on HVAC system. Performed thorough inspection of evaporator coil assembly, which showed moderate dust and particulate accumulation on the honeycomb mesh surface with visible discoloration throughout. Inspected drainage line and refrigerant conduit for proper operation and positioning. Removed and evaluated pleated air filter, which displayed dust buildup consistent with normal operational use. Filter frame and internal accordion-style pleated media were examined for structural integrity and airflow restriction. Verified all frame fasteners, rivets, and housing components were secure and properly sealed. System components were documented photographically for maintenance records.
HF G.
HF G. Checked in
Completed comprehensive 5-year ComfortGuard maintenance visit on HVAC system. Performed thorough inspection of evaporator coil assembly, which showed moderate dust and particulate accumulation on the honeycomb mesh surface with visible discoloration throughout. Inspected drainage line and refrigerant conduit for proper operation and positioning. Removed and evaluated pleated air filter, which displayed dust buildup consistent with normal operational use. Filter frame and internal accordion-style pleated media were examined for structural integrity and airflow restriction. Verified all frame fasteners, rivets, and housing components were secure and properly sealed. System components were documented photographically for maintenance records.
East Lansing, MI 48823
Completed annual HVAC maintenance on first of two systems, replacing air filter and humidifier pad per seasonal maintenance protocol. Verified thermostat operation showing proper heating mode function with accurate temperature display and setpoint control. System operating within normal parameters at time of service.
Completed annual HVAC maintenance on first of two systems, replacing air filter and humidifier pad per seasonal maintenance protocol. Verified thermostat operation showing proper heating mode function with accurate temperature display and setpoint control. System operating within normal parameters at time of service.
HF G.
HF G. Checked in
Completed annual HVAC maintenance on first of two systems, replacing air filter and humidifier pad per seasonal maintenance protocol. Verified thermostat operation showing proper heating mode function with accurate temperature display and setpoint control. System operating within normal parameters at time of service.
East Lansing, MI 48823
Conducted comprehensive estimate for complete HVAC system replacement at 28-year-old ranch-style home with forced air natural gas heating and air conditioning. Assessed existing furnace and AC unit located in closet installation, documented current system configuration including ductwork, refrigerant lines, electrical connections, and return air plenum with X-pattern damper assembly, and provided recommendations for full system upgrade to improve efficiency and reliability.
Conducted comprehensive estimate for complete HVAC system replacement at 28-year-old ranch-style home with forced air natural gas heating and air conditioning. Assessed existing furnace and AC unit located in closet installation, documented current system configuration including ductwork, refrigerant lines, electrical connections, and return air plenum with X-pattern damper assembly, and provided recommendations for full system upgrade to improve efficiency and reliability.
HF J.
HF J. Checked in
Conducted comprehensive estimate for complete HVAC system replacement at 28-year-old ranch-style home with forced air natural gas heating and air conditioning. Assessed existing furnace and AC unit located in closet installation, documented current system configuration including ductwork, refrigerant lines, electrical connections, and return air plenum with X-pattern damper assembly, and provided recommendations for full system upgrade to improve efficiency and reliability.
East Lansing, MI 48823
Completed comprehensive ComfortGuard Maintenance inspection on Lennox HVAC system. Performed thorough evaluation of furnace components including gas valve assembly, blower motor, control board, and all electrical connections. Verified thermostat operation and system controls, confirming proper temperature regulation and communication between thermostat and equipment. Replaced air filters as part of scheduled maintenance protocol. All components inspected and found operating within normal parameters with no issues identified.
Completed comprehensive ComfortGuard Maintenance inspection on Lennox HVAC system. Performed thorough evaluation of furnace components including gas valve assembly, blower motor, control board, and all electrical connections. Verified thermostat operation and system controls, confirming proper temperature regulation and communication between thermostat and equipment. Replaced air filters as part of scheduled maintenance protocol. All components inspected and found operating within normal parameters with no issues identified.
HF G.
HF G. Checked in
Completed comprehensive ComfortGuard Maintenance inspection on Lennox HVAC system. Performed thorough evaluation of furnace components including gas valve assembly, blower motor, control board, and all electrical connections. Verified thermostat operation and system controls, confirming proper temperature regulation and communication between thermostat and equipment. Replaced air filters as part of scheduled maintenance protocol. All components inspected and found operating within normal parameters with no issues identified.
East Lansing, MI 48823
Lorem Ipsum Gen Dolor

Ipsum Gen

Our Reviews

See What Your Neighbors Are Saying.

Angelo, Todd and Spencer installed the above and also a new hot water heater. Neat, clean professional installations and Todd did an excellent job More Info

Richard R.

Customer

Richard R.

Customer

My basement flooded during the last storm. Water heater and furnace pilots lights were out. Once service scheduler understood I was without hot water and More Info

Paulette H.

Customer

Paulette H.

Customer

Very professional crew. Could not be happier with out installation of our new furnace, ac unit and hot water heater. Highly recommended More Info

Mark J.

Customer

Mark J.

Customer

Great sales and service, everything Jeremy said would be done was. The system was completed and installed by two extremely professional technicians.

Herb

Customer

Herb

Customer

5 stars for Joe Rambo - came to assess my mini split within 2 hours of me requesting assistance.

Janice D

Customer

Janice D

Customer

Start Saving Today With

Membership Perks

What To Expect

Discover The Hager Fox Heating & Air Conditioning Difference

Preferred Dealer

We install, replace, repair, and maintain Mitsubishi & Lennox HVAC systems and Kohler generators.

Fully Licensed & Insured

Our experts are fully licensed and insured, with the skill to deliver the highest quality services every time.

100% Satisfaction Guarantee

We are committed to 100% satisfaction with any heating, cooling, or electrical service we perform.

One-Day Installs

Our expert technicians are highly trained and can install your new HVAC system in one day, guaranteed.

No Subcontractors

Our in-house team’s talent and knowledge allow them to handle any of our customers' requests without needing subcontractors.

Instant Rebates

Hager Fox Heating & Air Conditioning believes your time is precious, so we instantly process our rebates.

Preferred Dealer

We install, replace, repair, and maintain Mitsubishi & Lennox HVAC systems and Kohler generators.

Fully Licensed & Insured

Our experts are fully licensed and insured, with the skill to deliver the highest quality services every time.

100% Satisfaction Guarantee

We are committed to 100% satisfaction with any heating, cooling, or electrical service we perform.

One-Day Installs

Our expert technicians are highly trained and can install your new HVAC system in one day, guaranteed.

No Subcontractors

Our in-house team’s talent and knowledge allow them to handle any of our customers' requests without needing subcontractors.

Instant Rebates

Hager Fox Heating & Air Conditioning believes your time is precious, so we instantly process our rebates.

Our Reviews

See What Your Neighbors Are Saying.

Angelo, Todd and Spencer installed the above and also a new hot water heater. Neat, clean professional installations and Todd did an excellent job explaining the operational aspects. I couldn't be happier!

Richard R.

Customer

Richard R.

Customer

My basement flooded during the last storm. Water heater and furnace pilots lights were out. Once service scheduler understood I was without hot water and the furnance was also affected she wotked to schedule a same day appointment. She was courteous, friendly, and efficient. David was knowlegeable and efficient. My water hearter and furnace are very…

Paulette H.

Customer

Paulette H.

Customer

Very professional crew. Could not be happier with out installation of our new furnace, ac unit and hot water heater. Highly recommended 👌

Mark J.

Customer

Mark J.

Customer

Great sales and service, everything Jeremy said would be done was. The system was completed and installed by two extremely professional technicians.

Herb

Customer

Herb

Customer

5 stars for Joe Rambo - came to assess my mini split within 2 hours of me requesting assistance.

Janice D

Customer

Janice D

Customer

Ricardo and his crew are the best. They know what customer service means. They listened to our concerns, made sure all equipment was placed where we wanted, and are very knowledgeable and professional! They stayed till the job was finished. We thank Hager Fox for having the best technicians! We would definitely recommend them.

James S

Customer

James S

Customer

My furnace went out and I called several companies last night and Hager Fox was the only one that responded and came quickly to fix it!

Linda L.

Customer

Linda L.

Customer

Technician showed up on time, was very friendly and knowledgeable and got our furnace working properly again. Will definitely use them in the future.

Brandon H.

Customer

Brandon H.

Customer