Hager Fox Heating & Air Conditioning is your one-stop solution for HVAC, electrical, and water heater services in Okemos, MI. Our commitment to excellence is unmatched, with a legacy dating back to 1941. We don’t use subcontractors, ensuring that every service is handled by our licensed, insured, and NATE-certified technicians.
Contact Hager Fox Heating & Air Conditioning today at (517) 209-0130 and schedule a service that rocks.

Top-Rated Heating & Cooling Services
We offer top-rated heating and cooling services at Hager Fox Heating & Air Conditioning, specializing in ductless mini-splits, heat pumps, and gas or electric furnaces. Our services include:
- Installation & replacement: Our team provides expert installation and replacement services and customized solutions tailored to your needs and property requirements.
- Repair: We guarantee swift and reliable repair solutions for all HVAC systems and killed technicians equipped to diagnose and resolve issues efficiently, restoring comfort to your home.
- Maintenance: Our expert technicians offer tailored maintenance programs designed to preserve the efficiency and longevity of your HVAC systems. Hager Fox Air Care features exclusive benefits and priority service for members of our maintenance plans.
Air Quality Services in Okemos
Hager Fox Heating & Air Conditioning understands the importance of indoor air quality for your home. Improved IAQ offers numerous benefits, including better respiratory health, reduced allergens, and a more comfortable living environment.
Our comprehensive air quality solutions include:
- Air purifiers: Advanced air purifiers eliminate airborne contaminants like dust, pollen, and pet dander. These systems purify the air in your home, providing a fresh and clean living environment for you and your family.
- Air scrubbers: Cutting-edge air scrubbers remove odors, VOCs, and surface contaminants, ensuring a healthier indoor environment. They purify the air and surfaces in your home, creating a cleaner and more sanitized living space.
- Whole-home humidifiers & dehumidifiers: Whole-home humidifiers maintain optimal moisture levels, reducing dryness and improving overall comfort. Dehumidifiers control excess moisture, preventing mold and mildew growth while enhancing air quality.
Contact our professionals at (517) 209-0130 to schedule IAQ services and experience a healthier, more comfortable living space.
Superior Electrical Services
We pride ourselves on delivering superior electrical services for residential needs. From outlet wiring to whole-home generator installation, our comprehensive electrical solutions cover everything to keep your home powered and safe.
Our services include outlet wiring, electrical panels, outdoor and security lighting, ceiling fan installation, smart home device installation, and more. With a focus on top-priority electrical work, such as generators and EV charging stations, we ensure your home is equipped for modern electrical demands.
Contact us today at (517) 209-0130 to schedule reliable, top-quality electrical services that meet your needs and exceed your expectations.
Expert Water Heater Services
At Hager Fox, we are experts in providing top-notch water heater services. Whether it’s gas, electric, or tankless water heaters, our dedicated sections cover everything you need:
- Installation & replacement: We provide expert installation and replacement services for gas, electric, and tankless water heaters.
- Repair: Our skilled technicians are equipped to diagnose and address issues efficiently, restoring comfort to your home.
- Maintenance: Routine inspections and tune-ups ensure a consistent hot water supply and prevent unexpected breakdowns.
Call today at (517) 209-0130 to schedule same-day water heater repair and installation!
Choose Hager Fox Heating & Air Conditioning in Okemos
We are the preferred option for HVAC, water heater, and electrical services in Okemos, MI. Our licensed, insured, background-checked, and NATE-certified technicians provide replacement quotes and service call estimates. With financing options, instant rebates, and an unwavering commitment to excellence, we ensure 100% satisfaction guaranteed.
For service that rocks, call Hager Fox at (517) 209-0130 and schedule an HVAC, electrical, or water heater service today.
Recent Jobs and Reviews in Okemos, MI
Okemos, MI at a glance
Hager Fox Heating & Air Conditioning has completed 20 jobs in Okemos, MI between June 2026 and July 2026.
The most recent job was on July 2, 2026.
Hager Fox Heating & Air Conditioning has completed 275 jobs in Okemos, MI in the last 12 months.
Job Locations and Reviews
Completed on-site evaluation of 16-year-old HVAC system for replacement estimate. Inspected existing furnace with open access panel revealing burner assembly, internal components, and ductwork configuration in basement utility area. Evaluated exterior AC compressor/condenser unit mounted on turquoise equipment stand against building exterior. Assessed system for both partial component replacement options including compressor/condenser, inducer motor, and blower motor, as well as full system replacement recommendation due to age of equipment reaching end of typical service life.
Conducted site assessment for mini split installation in three season room with no existing HVAC equipment. Measured wall height and door frame dimensions to determine optimal indoor unit placement and evaluate installation requirements. Documented room specifications and photographed measurement locations to prepare detailed installation estimate.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, checked refrigerant pressures, and verified proper system operation. All components found to be functioning within normal parameters.
# HVAC Service Completed Responded to urgent no-cooling call affecting entire residence. Upon arrival, found outdoor condenser unit running but system failing to provide adequate cooling. Performed comprehensive diagnostic evaluation of split system air conditioning unit. Inspected outdoor condensing unit positioned on grade-level pad adjacent to structure. Unit showed signs of normal wear consistent with residential installation. Verified condenser fan motor operation and observed proper rotation. Checked electrical connections at disconnect box mounted on wooden stake near unit. Conducted refrigerant pressure analysis on both high and low-side service ports. Measured operating pressures and compared against manufacturer specifications for ambient conditions. Identified refrigerant charge deficiency affecting system capacity and cooling performance. Performed leak detection procedures using electronic leak detector on all refrigerant circuit components including condenser coil, se
Performed full system estimate on 1995 furnace and air conditioning unit located in basement. Unit has been non-operational for approximately one year with suspected control board failure. Completed diagnostic assessment of aging HVAC system, documented equipment condition through photographic documentation of basement installation including ductwork and equipment location. Provided comprehensive replacement options and recommendations due to advanced age of existing equipment beyond typical service life expectancy.
Conducted comprehensive assessment of existing forced air HVAC system for replacement estimate in single-family residence. Inspected 25-year-old outdoor air conditioning unit and Ruud Achiever furnace located in basement, documenting equipment dimensions, clearances, and current installation configuration. Measured spatial requirements around furnace unit and existing PVC venting system to determine replacement equipment specifications and installation feasibility. Photographed existing equipment, ductwork connections, and utility room layout to prepare detailed replacement proposal for complete heating and cooling system upgrade.
Performed comprehensive cooling system tune-up on residential HVAC unit. Inspected and evaluated air filtration system, noting accumulated dust and debris on pleated filters with diamond pattern mesh. Completed standard maintenance procedures including system performance verification, with all components operating within normal parameters and no deficiencies identified.
Completed annual cooling maintenance on Bryant air conditioning system. Replaced air filter, inspected condensing unit exterior condition and evaporator coil which showed significant corrosion and oxidation on copper refrigerant lines indicating age-related deterioration. All components operational at time of service completion.
Responded to non-operational air conditioning system that had been inoperative for approximately one year. Upon diagnostic inspection of 1995 vintage equipment located in basement, identified failed control board as primary cause of system failure. Visual inspection revealed corroded capacitor terminals with white crystalline deposits and rust-colored deterioration on motor component, indicating electrical degradation. Control board displayed multiple wire connections across various terminals with visible wear on PCB components. Documented equipment condition through photographic evidence showing extent of component deterioration and recommended complete control board replacement to restore system functionality.
Completed routine AC tune-up on 1-year-old central air conditioning system with no reported issues. Inspected evaporator coil and found moderate dust and debris accumulation on mesh surface; cleaned coil to restore optimal airflow and heat transfer efficiency. Replaced existing air filter with new FilterBuy MERV-rated filter to maintain proper system operation and indoor air quality.
Responded to service call for water dripping from central air conditioning system approximately 4 feet above floor level. Inspected condensate drainage system and cleared blockage from PVC drain line running along floor to drain outlet. Identified secondary leak source at elevated condensate line near air handler unit. Cleared algae buildup and debris from primary drain pan and secondary overflow port. Verified proper drainage flow through both primary and auxiliary drain lines. System tested and confirmed operational for cooling with no further water leakage observed during service visit.
Completed full package unit installation including mechanical reconnection of all components. Installed new digital programmable thermostat and verified proper system operation with temperature control functionality. All necessary permits were obtained prior to installation, and final system testing confirmed proper airflow and cooling performance.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of all components, and documented equipment condition with photographs. Unit found in good working order with no immediate service needs identified.
Responded to no cooling complaint on central air conditioning system. Upon arrival, found outdoor condenser unit with inoperative fan motor producing humming sound, indicating electrical failure or seized motor bearings. Diagnosed failed condenser fan motor on 6-9 year old residential split system AC unit. Replaced defective fan motor with OEM equivalent component, verified proper rotation and airflow. Tested capacitor and contactor operation, confirmed proper amperage draw and system pressures. Unit restored to full cooling operation with normal sound levels.
Responded to no cooling complaint with weak airflow and unresponsive Carrier Infinity thermostat. Diagnosed 10+ year old outdoor condenser unit and thermostat system, identifying communication failure between thermostat and air handler preventing temperature adjustment and proper system operation. Restored cooling functionality and verified thermostat control response.
Completed full HVAC system installation including a 70,000 BTU furnace with humidifier and 3-ton air conditioning unit. Indoor equipment installed on platform base in basement with proper condensate drainage via PVC piping, flexible ductwork connections, and refrigerant line sets between units. Outdoor Lennox condenser unit positioned on pad with electrical and refrigerant connections completed to manufacturer specifications.
Completed full HVAC system installation including a 90,000 BTU furnace with humidifier and 3.5-ton air conditioning unit with rear discharge configuration. All equipment was installed per manufacturer specifications, with PVC venting routed through basement ceiling joists and condensate drainage properly configured. The Lennox condenser was positioned on a protective pad with paver stone base against exterior wall, with all refrigerant lines connected and electrical reconnection completed. Mechanical permit was obtained prior to installation, and all work was performed in compliance with local building codes and industry standards.
Completed installation of 5-ton air conditioning system with matching evaporator coil in left-side configuration. Reconnected electrical service and verified proper operation of condensate pump system in basement location. Programmed and tested Lennox digital thermostat, confirming cooling cycle operation, humidity monitoring, and zone control functionality at 70-degree setpoint.
Completed full installation of 5-ton air conditioning system with matching evaporator coil at residential property. Positioned outdoor condenser unit on deck with proper condensate pan and installed electrical disconnect box with PVC conduit connections. Installed indoor air handler with evaporator coil in basement utility area, suspended horizontally with proper ductwork integration and support strapping. Reconnected all electrical connections, established refrigerant lines between indoor and outdoor units, and verified proper airflow through existing ductwork system. All work performed in accordance with mechanical permit requirements for left-side configuration installation.
Responded to callback regarding condenser coil condition following previous fuse replacement service. Performed visual inspection of outdoor unit and documented coil condition with photographs. Upon examination, condenser coils showed normal weathering and dirt accumulation consistent with outdoor exposure, but no structural damage or compromised fins were observed that would affect system operation or efficiency.