When it comes to your home’s HVAC, plumbing, and electrical service needs, having a trusted technician is essential for ensuring comfort, safety, and peace of mind. That’s where Hager Fox Heating & Air Conditioning comes in. We take pride in providing top-notch home services throughout East Lansing and the surrounding area.
If you’re seeking professional HVAC, water heater, or electrical services, look no further than Hager Fox. Schedule your service today by calling us at (517) 348-0412!
Dependable HVAC Services for East Lansing Families
At Hager Fox, we offer a wide range of HVAC services to cater to the unique needs of East Lansing families. Our expert technicians are skilled in handling various HVAC systems, including:
- Ductless mini-splits: Perfect for efficient zoned cooling and heating, providing individualized comfort for different areas of your home.Â
- Heat pumps: Versatile systems that heat and cool your home efficiently, ideal for moderate climates like East Lansing.Â
- Gas & electric furnaces: We specialize in installing, repairing, and maintaining furnaces to keep your home warm during the winter.Â
- Central AC: Our technicians are experienced in installing and servicing central air conditioning systems, ensuring you stay cool all summer.
Installation & Replacement
When it comes to HVAC installations and replacements, Hager Fox is your go-to service provider. If you notice any of the following signs, it might be time to consider upgrading your HVAC system:
- Frequent breakdowns and costly repairsÂ
- Rising energy bills indicating reduced efficiency
- Uneven heating or cooling throughout your home
- Outdated system unable to meet your family’s needs
Repair
HVAC systems can face various issues over time, affecting their performance and comfort. Count on Hager Fox for HVAC repair services to address a variety of common problems, such as:
- Airflow issues due to clogged filters or ductwork problems
- Thermostat malfunctions and inaccurate temperature readings
- Strange noises coming from the HVAC unitÂ
- Inconsistent heating or cooling
Maintenance
Preventative maintenance is critical to extending the life span of your HVAC equipment and avoiding costly repairs. Our HVAC maintenance services offer the following benefits:
- Improved system efficiency and energy savings
- Enhanced indoor air quality, promoting a healthier living environment
- Early detection of potential issues, preventing major breakdowns
- Prolonged HVAC system life span
East Lansing Air Quality ServicesÂ
At Hager Fox, we understand the importance of indoor air quality. We offer a variety of indoor air quality solutions suitable for a broad range of applications, including:
- Air purifiers: Remove pollutants, allergens, and particles from the air, promoting cleaner and fresher indoor air.Â
- Air scrubbers: Help eliminate odors, smoke, and volatile organic compounds from your home.Â
- Whole-home humidifiers & dehumidifiers: Maintain optimal humidity levels for better comfort and health.Â
Schedule indoor air quality services for your East Lansing home by calling Hager Fox at (517) 348-0412 today!
Reliable Water Heater Services
In addition to HVAC services, Hager Fox provides reliable water heater solutions to families throughout East Lansing and beyond. Our skilled technicians can handle:
- Water heater installation & replacement: Whether you prefer gas, electric, or tankless water heaters, we’ve got you covered with the best systems.
- Water heater repair: Prompt and efficient repair services to ensure hot water is always available when you need it most.
- Water heater maintenance: Regular maintenance to prevent breakdowns and extend the life of your water heater unit.
Get the fast, efficient water heater services you seek by calling (517) 348-0412 to schedule service with our water heater experts today!Â
Expert Electrical Services
Beyond heating, cooling, and water heaters, Hager Fox offers expert electrical services, including:
- Outlet & switch repair & replacement
- Electrical panel upgrades
- Circuit breakers
- Whole-home generators
- Lighting installation & repair
- Ceiling fan installation & repair
- Code corrections
- Appliance installation
- Wiring & rewiring
- And much more!
Allow our team to ensure functionality and safety in your home through our top-quality electrical solutions. Call (517) 348-0412 to request electrical service from Hager Fox today!
Why Choose Hager Fox Heating & Air Conditioning in East Lansing?
There are several reasons why Hager Fox should be your preferred choice for quality HVAC, water heater, and electrical services, including:
- Licensed & insured technicians: Our team consists of background-checked, NATE-certified technicians who deliver quality service with professionalism.Â
- Service all brands: We are well-equipped to handle the HVAC and electrical systems of all brands, including Lennox, Mitsubishi, and Kohler.Â
- Free estimates: We provide free estimates for replacement quotes and service calls, ensuring transparency and affordability.Â
- Financing options & instant rebates: We offer flexible financing options and instant rebates to make our services more accessible and budget-friendly.Â
- 100% satisfaction guaranteed: Customer satisfaction is our top priority, and we guarantee your complete satisfaction with our services.Â
Don’t hesitate to choose Hager Fox Heating & Air Conditioning for all your HVAC, water heater, and electrical service needs. Schedule your service today by calling (517) 348-0412 now!Â
Recent Jobs and Reviews in East Lansing, MI
Job Locations and Reviews
Responded to service call for water intrusion through water heater vent during heavy rainfall. Upon inspection, identified improper vent termination allowing rainwater to enter the flue system and drip from the atmospheric vent hood. Examined the galvanized vent pipe configuration and confirmed lack of adequate weather protection at the exterior termination point. Recommended installation of a proper vent cap or rain collar to prevent future water infiltration while maintaining proper draft and combustion air requirements for the natural draft gas water heater.
Conducted on-site evaluation for new tankless water heater installation in residential property. Assessed existing plumbing infrastructure, including copper supply lines and shut-off valves in utility area, and documented current water heater configuration. Provided comprehensive estimate for tankless unit installation, including necessary modifications to gas lines, venting requirements, and electrical connections to support on-demand water heating system.
Responded to commercial HVAC replacement estimate for non-heating furnace system located in utility room. Assessed existing Carrier furnace and air handler configuration with associated electrical panel, refrigerant lines, condensate drainage, and ductwork connections. Documented current equipment condition, internal blower motor assembly, control components, and existing installation setup including PVC piping, copper lines, and electrical connections to provide comprehensive replacement quote for failed heating system.
Responded to no heat call at residential property. Upon inspection of furnace located in utility room, discovered electrical wiring issues within the blower compartment and significant debris accumulation on heat exchanger tubes. Inspected all electrical connections, terminal blocks, and capacitor assembly. Documented condition of internal components showing signs of age and operational wear. Cleaned debris from heat exchanger surfaces and verified proper wire routing and connections throughout electrical compartment. System evaluated for safety and operational concerns.
Completed comprehensive ComfortGuard maintenance visit on residential HVAC system including air handler unit and associated mechanical equipment. Performed standard inspection protocols on all accessible components, verified proper operation of condensate drain lines, checked electrical connections and refrigerant line integrity, and inspected ductwork and filtration system. All equipment found in operational condition with organized connections and clean surfaces maintained throughout the mechanical room installation.
Completed annual preventative maintenance on outdoor air conditioning condenser unit. Connected manifold gauge set to service ports and verified refrigerant pressures and system operating parameters within manufacturer specifications. Unit inspected, tested, and confirmed operational with no deficiencies noted.
Responded to complaint of exhaust fumes from water heater leaking into living space. Upon inspection, identified compromised venting system on tanked water heater allowing combustion gases to escape into the home rather than properly exhausting outside. Disassembled and replaced defective PVC vent piping components, including multiple elbow fittings that showed signs of deterioration and mineral deposits. Reinstalled proper venting configuration to ensure safe exhaust of combustion gases and verified all connections were secure and properly sealed to prevent future leakage into occupied areas.
Completed installation of new residential gas furnace in basement mechanical room. Installed vertical air handler unit with proper ductwork connections, integrated humidifier system with water supply lines, and white PVC condensate drain piping with appropriate support brackets. All equipment mounted securely on basement floor with professional routing of drainage lines, electrical connections, and sealed metallic duct joints at supply plenum.
Responded to no heat call for forced air furnace system of unknown age. Upon inspection, assessed existing furnace and HVAC equipment configuration in basement mechanical room. Evaluated system condition and determined replacement was more cost-effective option than repair. Provided comprehensive estimate for complete furnace replacement, documenting existing equipment specifications, ductwork connections, and installation requirements. Photographed current system setup including furnace cabinet, humidifier unit, ductwork configuration, and internal components to support replacement quote and ensure proper equipment sizing for new installation.
# HVAC Maintenance - ACM Service Report Completed routine Air Conditioning Maintenance (ACM) on Lennox outdoor condensing unit. Performed comprehensive system inspection including visual assessment of electrical components, capacitor, contactor, and wiring connections. All electrical connections verified secure with proper wire routing observed. Capacitor examined and found in good operating condition with no signs of bulging or deterioration. Contactor terminals inspected and confirmed clean with no pitting or damage. Refrigerant lines and condensate drain checked for proper installation and functionality. Unit exterior panels and housing inspected with no structural concerns noted. System operational with no deficiencies identified during maintenance visit.
# Service Report Responded to no heat call on 1-year-old furnace located in basement. Upon arrival, conducted diagnostic inspection of unit with access panels removed to identify cause of heating failure. Inspected all internal components including blower motor assembly, gas valve, pressure switches, condensate drain system, and electrical connections throughout upper and lower compartments. Verified proper operation of all mechanical and electrical systems. Checked venting system including PVC exhaust and intake pipes for proper installation and clearances. Examined wiring connections and found some disorganization but all connections secure and functional. Restored heat to unit and confirmed normal operation. Completed Annual HVAC Maintenance inspection as time permitted, including full system evaluation and performance verification. Documented equipment condition with photos showing internal components and overall unit configuration. Unit operating properly at time of departure. Pa
# HVAC Install - Complete System ## Summary Successfully completed full HVAC system replacement including installation of 110,000 BTU furnace and 4-ton air conditioning unit with left-side configuration, humidifier integration, and reconnection of all existing utilities. ## Work Performed Removed existing HVAC equipment and installed new Lennox furnace system with 110,000 BTU heating capacity in basement mechanical room. Mounted furnace cabinet on concrete floor with proper clearances and secured unit to manufacturer specifications. Installed 4-ton air conditioning system with left-side refrigerant line configuration to match existing infrastructure. Connected air handler plenum to furnace discharge and secured all ductwork connections with appropriate sealing methods. Installed silver-insulated rectangular plenum above furnace unit and connected black flexible ductwork for proper air distribution. Integrated humidifier system into new furnace installation, connecting water supply
Completed installation of a complete HVAC system, including a 110,000 BTU furnace, 5-ton AC unit, and humidifier in residential location. System features Lennox equipment with proper PVC venting, new ductwork connections, and all components were successfully installed according to manufacturer specifications and local mechanical permit requirements.
Performed comprehensive evaluation of 32-year-old furnace and A/C system located in utility room. Unit is currently operational but at end of expected service life. Inspected exposed internal components including control board, wiring harness, and ductwork connections. Provided replacement options for complete system upgrade to improve efficiency and reliability.
Performed scheduled ComfortShield maintenance on 4-year-old Lennox system (warranty through 05-2026). Inspected and replaced air filter on furnace unit. System is functioning properly with no operational issues detected. Confirmed water heater (Rheem Performance) is in good working condition. All components are operating within manufacturer specifications.
Performed annual maintenance on recently installed furnace system. Inspected all internal components including wiring, controls, and mechanical parts. Verified proper operation of drainage/ventilation system with particular attention to PVC connections and elbow joints. Unit is operating within manufacturer specifications with no issues identified.
Performed diagnostic assessment on 13-year-old non-operational furnace located in basement. System exhibited zero activity when calling for heat. Visual inspection of the unit revealed potential issues with the ignition system and possible control board malfunction that will require replacement of components to restore heating functionality.
Performed routine maintenance on forced air furnace reporting no heat. Inspected and cleaned flame sensor with abrasive pad to remove corrosion buildup that was causing system failure. System now functioning properly with restored heating operation.
Performed tune-up service on Bryant gas furnace. Discovered significant rust and corrosion around the heat exchanger and drainage components. Cleaned clogged condensate line to restore proper drainage and addressed startup noise by lubricating moving parts and securing loose components.
Conducted a comprehensive assessment of a non-operational mini split system in the kitchen area. Visual inspection revealed a wall-mounted unit installed above stainless steel cabinets requiring service. System was previously installed in 2023 and is now being evaluated for potential air conditioning repairs or replacement.